Customization: | Available |
---|---|
Type: | Solid-Liquid Separation |
Usage: | Environmental Protection, Chemical Industry |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | TPX11 | TPX22 | TPX34 | TPX75 | TPX100 | TPX136 |
Filter area(cm2) | 0.11 | 0.22 | 0.34 | 0.75 | 1.00 | 1.36 |
Volume (L) | 16 | 30 | 50 | 145 | 195 | 320 |
Inlet/Outlet (mm) | DN40-DN50 | DN50-DN80 | DN50-DN100 | DN65-DN100 | DN80-DN125 | DN100-DN150 |
Drain outlet (mm) | DN40 | DN50 | ||||
Applicable liquid | Viscidity (<800000cps), Impurity<1000ppm | |||||
Filtration Precision | 50-500μm | |||||
Std design P | 1.0MPa( High design pressure available) | |||||
Designed temp. | 0-200ºC( Determined by the seal material) | |||||
Cleaning pressure diff. | 0.05MPa | |||||
Diff pressure switch | Differential pressure transmitter(DPT) or Differential pressure switch(DPS) | |||||
Gear motor | 180W,380V, IP55 | |||||
Filter element type | V-SLOT, 316L | |||||
Housing material | 304/316L/CS | |||||
Scraping blade material | 304/316L | |||||
Seal material | NBR/VITON(FKM) | |||||
Discharging valve | ,IP65 Pneumatic ballvalve, protection class IP65 | |||||
Supply facility | 380V AC,0.4-0.6MPa ( Clean and dry compressed air) |
Filtering Process
Raw water enters the inside of the screen-cylinder from the filter's Inlet and flows through the screen to the filter's Outlet. The dirt particles are trapped on the inner screen surface and formulate a "filtration cake" that causes a differential pressure across the screen.
A pressure differential switch senses the pressure differential and when it reaches the pre-set value, the cleaning process begins.
Self Cleaning Process
During the self cleaning process, filtered process water continues to flow. The Drain Valve opens and the Motor rotates the stainless steel brush which sweeps the inner surface of the cylindrical screen. The particles trapped on the screen are dislodged by the brushes and flushed out the drain valve.
The whole process takes 20-30 seconds.
During the whole process water supply is uninterrupted.
Control System
Two types of control boards are available for the A700 filters: PLC/Timer.
The self cleaning cycle begins under any one of the following conditions
1. Receiving a signal from the Pressure Differential Switch
2. Time interval parameter set at the control board
3. Manual Start
About us
Top machinery, founded in 2002, and specialized in ETP, STP, WWTP equipment manufacture and wastewater solution, our products include screw type sludge dewatering equipment, DAF, sludge scraper, intergrated sewage treatment equipment, sludge dryer, self-cleaning filter, inward/outward water micro filter, screen, etc.
With our consistent effort, high quality, competitive price and good after-service, our plants are supplied to more than 30 countries, widely used in the fields of municipal and industry sewage, petro chemical, pulp and paper, printing and dyeing, leather, plastic recycling, food processing, farms, slaughterhouse, etc.